Technical characteristics
JNYQ-TPF-01 Temperature, Pressure, and Flow Integrated Monitoring Instrument
The temperature, pressure, and flow monitoring instrument uses the Pitot tube method to measure the flow velocity of flue gas. The Pitot tube, pressure sensor, and temperature sensor are used to measure the dynamic pressure, static pressure, and temperature of the flue gas. These parameters are proportional to the measured flue gas flow velocity, and can be used to quantify the flow velocity of the flue gas.
Detailed description
• It can measure the flow rate, dynamic pressure, static pressure, and temperature of flue gas in real time, and actively output 4-20mA through 4 analog signals.
• Automatic timing or manual zero calibration of dynamic pressure and flow rate.
• LCD displays various measurement data and signals, which can be directly read for easy debugging.
• High measurement accuracy, good reliability, and can work continuously for a long time.
• The split structure and pitot tubes have a 300mm adjustable range for expansion and contraction.
• Equipped with an automatic backwash unit, it can regularly clean the particles inside the pitot tube, and the backwash interval time can be set.
• Equipped with an air tank, ensuring sufficient pulse back blowing air for effective blowing.
• Easy installation and wiring, low maintenance.
• Small size, compact structure, and requires small installation space.
Measurement principle and structure
The temperature, pressure, and flow monitoring instrument uses the Pitot tube method to measure the flow velocity of flue gas. Using Pitot tubes, pressure sensors, and temperature sensors to measure the dynamic pressure, static pressure, and temperature of flue gas, these parameters are proportional to the measured flue gas flow rate, thus allowing for quantitative measurement of the flue gas flow rate. The S-type pitot tube and armored thermistor are made of 316L stainless steel material with high corrosion resistance, and are combined with a 316L stainless steel protective sleeve and a fixed outer nut to form an integrated pitot tube and temperature probe.

Technical indicators
|
|
Parameter range |
Display resolution |
Signal output |
Accuracy |
Output resolution |
|
Smoke flow rate |
(0~40)m/s |
0.1m/s |
(4 ~ 20)mA |
±2%FS |
0.125%FS |
|
Dynamic pressure of flue gas |
(0~1000 )Pa |
1Pa |
(4 ~ 20)mA |
±2%FS |
0.125%FS |
|
Smoke static pressure |
(60~140) kPa (absolute pressure) |
0.1kPa |
(4 ~ 20)mA |
±1 %FS |
0.125%FS |
|
Smoke temperature |
(0 ~ 500 )℃ |
0.1℃ |
(4 ~ 20)mA |
±1%FS |
0.125%FS |
Blowback unit
• Electromagnetic valve power supply: 220VAC, blowback time
• Blowback gas source: instrument gas, pressure is 0.3~0.8MPa (gauge pressure)
• Automatic zero calibration: The interval time can be set to automatically calibrate the zero points of dynamic pressure and flow rate.
• Pitot tube length: 1000mm, 1500mm, 1800mm; Each pitot tube has a 300mm expansion and contraction adjustment range
• Case size: 335mm x 230mm x 100mm
• Total weight (including flange): approximately 10kg
• Installation environment requirements: temperature: -25~65 ℃, vibration: acceleration less than 1g
• Working power supply: 220VAC, 1.5A
Key words:
Flue gas analyzer, flue gas online monitoring, VOCS online monitoring, waste incineration online monitoring
Classification:
online message
Note: Please fill in the above information correctly so that we can feedback the processing results to you at the first time!
The JNYQ-S-81 flue gas analyzer is a gas analyzer product independently developed for online gas analysis of environmental protection and industrial control sites both domestically and internationally. This analyzer is based on the principle of ultraviolet absorption spectroscopy technology and can measure the concentration of gases such as SO2, NO, NO2, O2, etc. It has the characteristics of high measurement accuracy, high reliability, fast response time, and wide applicability. Its various indicators meet or exceed similar products at home and abroad, and can be widely used in environmental online monitoring, industrial control, safety monitoring, and other occasions.
TR-9100 Cement Process Gas Online Analysis System
The TR-9100 system is a gas composition analysis safety interlock device specially designed for the safe operation of cement plants. A solution provided based on targeted design using the mature analysis and control technology and sampling pretreatment technology of JuNeng Company to address the harsh working conditions of cement plants in China. Especially with the use of technologically innovative sampling probes with minimal maintenance, they are more suitable for the harsh working conditions of high dust cement in China.
TR-9300A miniature air quality monitoring system
The TR-9300A miniature environmental air quality monitoring system adopts light scattering and high-precision electrochemical detection technology. It is a high-performance sensing and collection device that integrates air six parameter monitoring (PM2.5, PM10, SO2, NO2, O3, CO), GPS positioning, and 4G communication. It has high integration, strong scalability, easy installation, and high sensitivity and reliability. It can be deployed in a grid form in various areas such as urban residential areas, business and office areas, industrial parks, transportation roads, and construction sites, to continuously monitor the air quality of the target area 24/7, providing basic data for comprehensive evaluation of urban air quality.
TR-9300D flue gas ultra-low emission continuous monitoring system
Xi'an Juneng Instrument Co., Ltd. has successfully launched the TR-9300D ultra-low emission continuous monitoring system for flue gas, based on years of research and application experience in environmental monitoring systems. The system is based on relevant standards and specifications such as HJ/T76-2007 and HJ/T75-2007. The analytical instrument used is the JNYQ-S-81 flue gas analyzer independently developed by Xi'an Juneng Instrument Co., Ltd. A single monitoring system adopts an architecture mode of monitoring platform probe+preprocessing+industrial computer+LCD display+data acquisition instrument to complete the functional requirements of receiving, storing, displaying, and transmitting monitoring data.
JNYQ-I-41 infrared gas analyzer
A new type of infrared gas analyzer designed and manufactured using the principle of non dispersive infrared for infrared analysis instruments
JNYQ-I-44Ex infrared gas analyzer
The JNYQ-I-44Ex model has an explosion-proof structure, which can be safely and reliably used in petroleum refining, chemical industry, natural gas, and other flammable and explosive environments